We are committed to providing high quality analyzing solution to global customers over the world.

POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Toxic and Harmful Gas Analyzer
POGA-100 Portable Gas Analyzer is developed for detection and warning of accident odor emission, comparative investigation of pollution sources, and rapid detection of ambient air odor gas. The analyzer is designed based on ultraviolet differential absorption spectrum (DOAS) technology.
B2B does not have purchase function
库存: 0
Inquire
Add to Basket

POGA-100 Portable Gas Analyzer is developed for detection and warning of accident odor emission, comparative investigation of pollution sources, and rapid detection of ambient air odor gas. The analyzer is designed based on ultraviolet differential absorption spectrum (DOAS) technology.

It can detect a variety of odorous gases simultaneously. And it can be expanded to detect TVOCs, benzene, methylbenzene and other gases according to user needs. Besides, it can also be configured with high-temp heating pipeline, and condensation pretreatment system, so that to achieve monitoring of odor gas and flue gas pollutants simultaneously.


• Monitoring of unorganized emission sources from enterprises or chemical industry park;

• Monitoring of odorous gas emissions from municipal sewage treatment plant and waste incineration power plant;

• Quick analysis of for emergency dangerous emission exhaust;

• Odor discharge monitoring of residential area


Measurement principle:

UV-DOAS: C2H6S, C2H6S2 , CH3SH, C3H9N, C8H8, CH4S, CS2, H2S, NH3 , etc;

PID: TVOCs ;

Empirical formula: OU ;

Measuring range:

C2H6S, C2H6S2, CH3SH, C3H9N, CH4S, H2S, NH3 : 0~5 ppm

C8H8, CS2, TVOCs: 0~10 ppm

OU: 0~5000

Repeatability:

≤ ±3%

Indication error:

≤ ±5%F.S.

Zero drift:

≤ ±1%F.S./24h

Span drift:

≤ ±3%F.S./24h

Response time(T90):

≤120 s

Calibration gas:

Zero calibration gas: clean air or dry nitrogen gas;

Range calibration gas: the concentration is 90% ~110% of the range of each measured component. The concentration out of this range should not be used.

Communication protocol:

Modbus – RTU

Communication interface :

RS485, RS232, Ethernet

Digital input:

4 inputs, can be configured

Digital output:

4 inputs, can be configured

Power supply:

(220±22)VAC, 50/60Hz, 120W

Enclosure Rating:

IP54

Working temperature:

-10℃ ~ 30℃

Working humidity:

≤85%RH, non condensation

Dimension:

510(W)×25(D)×20(H) mm

Weight:

Approx. 20Kg